default_estimated_departure_time_deltastring<duration>required

The time a vehicle is expected to charge expressed in ISO 8601 time delta, this will be used if we receive an AC transaction with this profile_id, without an estimated departure time.

default_requested_min_energyDefault Requested Min Energy (integer)required

The default requested minimum energy (Wh) for AC transactions with this profile, this will be used if we receive a transaction with this profile_id, without a requested minimum energy.

default_requested_max_energyDefault Requested Max Energy (integer)required

The default requested maximum energy (Wh) for AC transactions with this profile, this will be used if we receive a transaction with this profile_id, without a requested maximum energy.

default_minimal_charging_current object

The minimal charging current (in Amperes) for AC transactions with this profile. When set, this site-level minimum is applied to every AC transaction with this profile, overriding the per-transaction value. Used to compute minimum power constraints.

anyOf
number
default_allow_zero_current object

Whether AC transactions with this profile allow zero current charging periods. When set, this site-level value is applied to every AC transaction with this profile, overriding the per-transaction value. A vehicle that physically cannot pause charging still forces zero current to be disallowed regardless of this setting.

anyOf
boolean
AcChargingProfile
{
"default_estimated_departure_time_delta": "PT8H",
"default_requested_min_energy": 20000,
"default_requested_max_energy": 30000,
"default_minimal_charging_current": 6,
"default_allow_zero_current": false
}